Segmented Display AS01
Individually programmable Floor indicator
Font size 30 mm / 16 - Segment
Fluorescent colours red, green
Additional connection for indication of driving direction SA35-PF
Especially narrow design for door case installation


|
Controls :
|
Graycode, 1 out of N, Binarycode
|
|
Supply Voltage:
|
12 - 24 V / DC
|
|
Power consumption:
|
without Arrow SA 35-PF = 12V approx. 90mA / 24V approx.
70mA
with Arrow SA 35-PF = 12V approx. 130mA / 24V approx. 100mA |
|
Connection:
|
Screw connectors , Ribbon cable / 16 pin,
RJ45 (Patch-) cable, 8 pin + shield, Cat 5 Ribbon cable / 10 pin for SA 35-PF |
Display is mounted by 2 welded-stud fasteners M 3 x 30 on the rear of the
face plate.
Thickness of face plate: 2 mm
| Pin configuration FBK 16 pin |
Pin configuration Screw connectors | Signal Graycode Max. 49 Stops | Signal 1 out of N Max. 8 Stops |
Pin configuration RJ 45 Signal Graycode 15 Stops |
| 1 | 1 | Graycode A | picture 1 | 1=Graycode A |
| 2 | 2 | Graycode B | picture 2 | 2=Graycode B |
| 3 | 3 | Graycode C | picture 3 | 3=Graycode C |
| 4 | 4 | Graycode D | picture 4 | 4=Graycode D |
| 5 | 5 | Graycode E | picture 5 | |
| 6 | 6 | Graycode F | picture 6 | |
| 7 | UP | Arrow up | Arrow up | 5=Arrow up |
| 8 | DN | Arrow down | Arrow down | 6=Arrow down |
| 9 | - | Minus (-) | Minus (-) | 7=Minus (-) |
| 10 | + | Plus (+) | Plus (+) | 8=Plus (+) |
| 11 | 7 | picture 7 | ||
| 12 | 8 | picture 8 | ||
|
Pin 13 - 16 = not connected
If a 2 digit floor and a driving direction display is required, please add the arrow display SA 35-PF |
||||
| Pin configuration Ribbon cable 10 pin Connection SA 35-PF | 7 = Arrow up | 9 = Minus (-) |
| 8 = Arrow down | 10 = Plus (+) |
| 16 Seg. Anzeige
AS 2x16-30 freely-programmable , double digit , 30mm |
Red | AS0101 | |
| Green | AS0102 |
Dimension Diagram

Cover plate cut-out
Installation depth with standard connection min. 45 mm